Controls fundamentals, equipment sequences, networks and commissioning.

Start the first lesson
Activity library progress0 of 31 activitiesSaved in this browser
Track 01

Controls foundations

Map familiar HVAC equipment and troubleshooting habits to BAS points, controllers, sequences, and front-end graphics.

Controls foundations activities, formats, durations and completion status
ActivityFormatDurationProgress
Point types, signals, and physical proofIdentify what a point represents, scale its signal, and separate a command from equipment response.Lesson · 12 minLesson12 minOpen
Command versus proofSeparate controller intent from physical equipment status, then prove the first failed boundary.Lesson · 18 minLesson18 minOpen
Setpoints, process values, and PIDRead a feedback loop in context and understand why error, timing, and sequence permissions all matter.Lesson · 14 minLesson14 minOpen
Alarms, command priorities, and overridesDistinguish an alarm condition from acknowledgement and identify which command currently owns a point.Lesson · 12 minLesson12 minOpen
Trends and diagnostic evidenceBuild a useful trend bundle, preserve time context, and choose an observation that distinguishes competing explanations.Lesson · 12 minLesson12 minOpen
Track 02

Airside diagnostics

Trace airflow, compare commands with feedback, inspect control logic, and diagnose seven realistic operating cases.

Airside diagnostics activities, formats, durations and completion status
ActivityFormatDurationProgress
Commissioning baselineEstablish normal point relationships before troubleshooting.Lab · 8 minLab8 minOpen
Afternoon comfort callDecide whether high output means equipment failure.Lab · 10 minLab10 minOpen
Low-airflow callSeparate a loaded filter from a fan controls problem.Lab · 10 minLab10 minOpen
Ventilation complaintCompare damper command, feedback, and CO₂ response.Lab · 10 minLab10 minOpen
Sensor disagreementRecognize when a normal-looking graphic is lying.Lab · 10 minLab10 minOpen
Fan will not proveFollow a binary sequence from command to status.Lab · 10 minLab10 minOpen
Cold-weather shutdownTrace freeze protection and safety priority.Lab · 10 minLab10 minOpen
Fan-coil unit operating labTrace a local return-air, fan, coil, valve, discharge-air, and condensate-safety loop separately from the AHU.Lab · 15 minLab15 minOpen
Track 03

BAS protocols & integration

Read BACnet MS/TP evidence, verify object capabilities and command ownership, and validate Modbus register mapping without live writes.

BAS protocols & integration activities, formats, durations and completion status
ActivityFormatDurationProgress
BACnet MS/TP fault isolationDiagnose duplicate addresses, baud mismatch, polarity faults, and poor termination on a simulated trunk.Lab · 25 minLab25 minOpen
BACnet objects, priorities & secure accessIdentify the actual point, distinguish a stale value from a controlled output, and understand the boundary of BACnet/SC.Lesson · 18 minLesson18 minOpen
Modbus register mapping and credible valuesDistinguish a successful read from a correctly mapped measurement using function, offset, data type, scaling and units.Lesson · 18 minLesson18 minOpen
Track 04

Refrigeration controls

Follow pump-down, defrost, superheat control, compressor protection, head pressure and capacity staging.

Refrigeration controls activities, formats, durations and completion status
ActivityFormatDurationProgress
Pumpdown: follow the complete control sequenceConnect room demand, the liquid-line solenoid, suction pressure and compressor operation without mistaking an operating stop for a fault.Lesson · 14 minLesson14 minOpen
Defrost: termination, drainage and fan delayRead the operating state before deciding that a stopped compressor, heater or evaporator fan has failed.Lesson · 16 minLesson16 minOpen
Superheat: TXV behavior and EEV evidenceCalculate superheat at the correct location, then distinguish a sensing or configuration problem from a metering-valve fault.Lesson · 18 minLesson18 minOpen
Compressor protection: identify the initiating eventReconstruct a protective shutdown and repeated restart pattern using the first event, reset behavior and actual operating evidence.Lesson · 15 minLesson15 minOpen
Head pressure: understand low-ambient symptomsDistinguish refrigerant-feeding symptoms from their causes and identify which pressure a low-ambient regulating valve actually senses.Lesson · 15 minLesson15 minOpen
Rack staging: requested, available and running capacityInterpret suction-group demand and condenser control while separating a capacity request from a permitted compressor start.Lesson · 17 minLesson17 minOpen
Refrigeration sequence & evidence labExplore the sequence and pass five fictional field cases using diagnosis, key evidence and the next action.Lab · 25 minLab25 minOpen
Track 05

HVAC sequences & plant

Investigate economizers, VAV reset tradeoffs, hydronic circulation and plant permissions with source-grounded exercises.

HVAC sequences & plant activities, formats, durations and completion status
ActivityFormatDurationProgress
Economizers and outdoor-air evidenceRead economizer operation using mode, sensor credibility, mixing behavior, and the actual equipment sequence.Lesson · 16 minLesson16 minOpen
VAV airflow and coordinated AHU resetsConnect terminal airflow demand to duct pressure and supply-air temperature without treating one zone as the whole building.Lesson · 16 minLesson16 minOpen
Hydronic flow, valves, and ΔTSeparate valve request, water flow, pressure, and temperature difference when investigating coil performance.Lesson · 15 minLesson15 minOpen
Track 06

Checkout & commissioning

Verify points and functional behavior against documented requirements, then record evidence and restoration.

Checkout & commissioning activities, formats, durations and completion status
ActivityFormatDurationProgress
Commissioning with evidenceTurn an intended sequence into a bounded test with observations, acceptance criteria, restoration, and follow-through.Lesson · 15 minLesson15 minOpen
Track 07

BAS platforms & operations

Compare vendor engineering workflows, validate integration and security boundaries, rationalize alarms and test schedules with a capstone plan.

BAS platforms & operations activities, formats, durations and completion status
ActivityFormatDurationProgress
Vendor architectures & the right service toolRecognize the operator, supervisor and equipment-controller layers, then choose a compatible tool before changing a sequence.Lesson · 20 minLesson20 minOpen
BAS protocols, gateways & secure integrationRecognize the framework, network and protocol; validate a gateway point; and explain which links are actually secured.Lesson · 22 minLesson22 minOpen
Actionable alarms & fault detectionUse valid operating evidence to detect faults, reduce nuisance notifications and connect each alarm to a responsible response.Lesson · 20 minLesson20 minOpen
Schedules, bounded sequences & an integration capstoneTrace effective occupancy through valid inputs, operating permissions, bounded control and physical evidence, then plan a documented capstone test.Lesson · 24 minLesson24 minOpen